Featured Articles

Impact of Injection-Based Delivery Parameters on Local Distribution Volume of Ethyl-Cellulose Ethanol Gel in Tissue and Tissue Mimicking Phantoms

Impact of Injection-Based Delivery Parameters on Local Distribution Volume of Ethyl-Cellulose Ethanol Gel in Tissue and Tissue Mimicking Phantoms

Impact of Injection-Based Delivery Parameters on Local Distribution Volume of Ethyl-Cellulose Ethanol Gel in Tissue and Tissue Mimicking Phantoms 789 444 IEEE Transactions on Biomedical Engineering (TBME)
We explored the impact of injection-based parameters on resulting distribution of our ethanol gel at a scale relevant to human applications, particularly how to best deliver it into the cervix. read more
Prosthetic Limb Attachment via Electromagnetic Attraction through a Closed Skin Envelope

Prosthetic Limb Attachment via Electromagnetic Attraction through a Closed Skin Envelope

Prosthetic Limb Attachment via Electromagnetic Attraction through a Closed Skin Envelope 789 444 IEEE Transactions on Biomedical Engineering (TBME)
This paper introduces a novel method for attaching prosthetic limbs to the body using magnetic attraction, and presents an initial feasibility study for attachment at the transfemoral amputation level. read more
Automatic Stub Avoidance for a Powered Prosthetic Leg over Stairs and Obstacles

Automatic Stub Avoidance for a Powered Prosthetic Leg over Stairs and Obstacles

Automatic Stub Avoidance for a Powered Prosthetic Leg over Stairs and Obstacles 1805 1201 IEEE Transactions on Biomedical Engineering (TBME)
The paper utilizes environmental information from an ultrasonic sensor to reduce the risk of powered prosthetic leg stubbing on obstacles and stairs, improving safety without compensations from the users. read more
In Vivo Optical Coherence Elastography Unveils Spatial Variation of Human Corneal Stiffness

In Vivo Optical Coherence Elastography Unveils Spatial Variation of Human Corneal Stiffness

In Vivo Optical Coherence Elastography Unveils Spatial Variation of Human Corneal Stiffness 767 432 IEEE Transactions on Biomedical Engineering (TBME)
We proposed a high-frequency optical coherence elastography technique for in vivo mapping of human corneal stiffness. For the first time, we observed notable stiffness variations from the central to peripheral regions of the cornea. read more
Smart Capsule for Targeted Detection of Inflammation Levels Inside the Gi Tract

Smart Capsule for Targeted Detection of Inflammation Levels Inside the Gi Tract

Smart Capsule for Targeted Detection of Inflammation Levels Inside the Gi Tract 427 240 IEEE Transactions on Biomedical Engineering (TBME)
Novel smart capsule enables region-specific GI inflammation monitoring with integrated MPO sensor and low-power wireless communication, revolutionizing personalized IBD management. read more
Transmission Coefficient-Based Monitoring of Microwave Ablation: Development and Experimental Evaluation in Ex Vivo Tissue

Transmission Coefficient-Based Monitoring of Microwave Ablation: Development and Experimental Evaluation in Ex Vivo Tissue

Transmission Coefficient-Based Monitoring of Microwave Ablation: Development and Experimental Evaluation in Ex Vivo Tissue 768 432 IEEE Transactions on Biomedical Engineering (TBME)
We demonstrate the feasibility of monitoring microwave ablation zone growth with the same antennas used for delivering ablation, potentially offering a means for real-time intraprocedural assessment. read more
Measurement and Analysis of In Vivo Gastroduodenal Slow Wave Patterns Using Anatomically-Specific Cradles and Electrodes

Measurement and Analysis of In Vivo Gastroduodenal Slow Wave Patterns Using Anatomically-Specific Cradles and Electrodes

Measurement and Analysis of In Vivo Gastroduodenal Slow Wave Patterns Using Anatomically-Specific Cradles and Electrodes 789 444 IEEE Transactions on Biomedical Engineering (TBME)
This study describes novel measurement and analysis methods for in vivo bioelectrical slow waves and documents physiological phenomena in high-resolution across the gastroduodenal junction for the first time. read more
Sensing and Controlling Strategy for Upper Extremity Prosthetics Based on Piezoelectric Micromachined Ultrasound Transducer

Sensing and Controlling Strategy for Upper Extremity Prosthetics Based on Piezoelectric Micromachined Ultrasound Transducer

Sensing and Controlling Strategy for Upper Extremity Prosthetics Based on Piezoelectric Micromachined Ultrasound Transducer 712 356 IEEE Transactions on Biomedical Engineering (TBME)
A novel wearable A-mode ultrasound system based on PMUTs enables accurate gesture recognition, simplifies probes, eliminates the need for gel and complex circuits, promising simplified prosthetic control. read more
FLEX: FLexible transducer with EXternal tracking for ultrasound imaging with patient-specific geometry estimation

FLEX: FLexible transducer with EXternal tracking for ultrasound imaging with patient-specific geometry estimation

FLEX: FLexible transducer with EXternal tracking for ultrasound imaging with patient-specific geometry estimation 1920 1080 IEEE Transactions on Biomedical Engineering (TBME)
This study presents the patient-specific flexible ultrasound probe geometry estimation for real-time imaging with accurate anatomical structure and encourages utilizing the proposed imaging concept for image-guided interventions. read more
Biomechanical MEMS Electrostatic Energy Harvester for Pacemaker Application: a study of optimal interface circuit

Biomechanical MEMS Electrostatic Energy Harvester for Pacemaker Application: a study of optimal interface circuit

Biomechanical MEMS Electrostatic Energy Harvester for Pacemaker Application: a study of optimal interface circuit 700 394 IEEE Transactions on Biomedical Engineering (TBME)
This work presents a solution to extend the battery lifetime by converting biomechanical heartbeats energy into electricity using an innovative electrostatic MEMS energy harvesting device. Based on the energy consumed by the latest generation of leadless commercial pacemakers, this solution has experimentally demonstrated the possibility of extending pacemaker battery life by up to 44%, and holds out the prospect of total battery replacement. read more