Posts By :

dziura

Totally Implantable Oxygen Generator (TIOG) for Hypoxia and Hypoxemia

Totally Implantable Oxygen Generator (TIOG) for Hypoxia and Hypoxemia 789 444 IEEE Transactions on Biomedical Engineering (TBME)
Introducing TIOG, an ultra-low powered, implantable, wirelessly operatable platform to deliver tailored oxygen therapy based on precisely controlled electrolysis to reverse cancer hypoxia. read more

An efficient and multi-focal focused ultrasound technique for harmonic motion imaging

An efficient and multi-focal focused ultrasound technique for harmonic motion imaging 789 444 IEEE Transactions on Biomedical Engineering (TBME)
We developed a new harmonic motion imaging (HMI) system with electronic beam steering and multi-foci capability, which allows for faster and more flexible characterization of tissue mechanical properties. read more

Intracranial EEG Recordings of High-frequency Activity from a Wireless Implantable BMI Device in Awake Nonhuman Primates

Intracranial EEG Recordings of High-frequency Activity from a Wireless Implantable BMI Device in Awake Nonhuman Primates 789 444 IEEE Transactions on Biomedical Engineering (TBME)
We confirmed the functionality of a wireless implantable device in recording and transmitting electrocorticography (ECoG) signals with both millisecond precision and recording stability. The results provide confidence that this wireless device can be a translational tool for future fundamental neuroscientific studies in free-moving models and brain-machine interface applications. read more

Automatic Assessment of optimal electrodes placement for robust fetal heart rate detection from multichannel electrophysiological measurements through Blind Source Separation techniques

Automatic Assessment of optimal electrodes placement for robust fetal heart rate detection from multichannel electrophysiological measurements through Blind Source Separation techniques 1052 592 IEEE Transactions on Biomedical Engineering (TBME)
Guidelines and algorithms are provided to determine the best electrode configuration for fetal-heart-rate (fHR) monitoring by multichannel electrocardiography, considering source-signal characteristics, fHR-estimation algorithms, and dynamically adapting to fetal presentation. read more
Acoustic Force Elastography Microscopy

Acoustic Force Elastography Microscopy

Acoustic Force Elastography Microscopy 789 444 IEEE Transactions on Biomedical Engineering (TBME)
Acoustic force elastography microscopy (AFEM) can be used to observe the spatial variation of mechanical properties of hydrogels in a non-contact manner and address the limitations of destructive mechanical testing measurements. read more
Experimental Investigation of Microfluidic Device for Platelet Activation

Experimental Investigation of Microfluidic Device for Platelet Activation

Experimental Investigation of Microfluidic Device for Platelet Activation 789 444 IEEE Transactions on Biomedical Engineering (TBME)
We have developed microfluidic devices to activate platelets by using shear-induced platelet activation approach. These biomedical devices can be used in Platelet-rich plasma treatments without any adverse immune reaction. read more
Minimally Invasive Implant Type Electromagnetic Biosensor for Continuous Glucose Monitoring System: In vivo Evaluation

Minimally Invasive Implant Type Electromagnetic Biosensor for Continuous Glucose Monitoring System: In vivo Evaluation

Minimally Invasive Implant Type Electromagnetic Biosensor for Continuous Glucose Monitoring System: In vivo Evaluation 780 444 IEEE Transactions on Biomedical Engineering (TBME)
A fundamentally new approach for the development of EM-based implantable glucose sensor and initial in vivo experiments with C57BL/6J mouse and Sprague Dawley rat for continuous glucose monitoring is presented. read more
3-D Path-Following Control for Steerable Needles with Fiber Bragg Gratings in Multi-Core Fibers

3-D Path-Following Control for Steerable Needles with Fiber Bragg Gratings in Multi-Core Fibers

3-D Path-Following Control for Steerable Needles with Fiber Bragg Gratings in Multi-Core Fibers 789 444 IEEE Transactions on Biomedical Engineering (TBME)
This is the first study to demonstrate the safety and performance benefits of fiber Bragg gratings in multi-core fibers for autonomous steerable needle navigation, implemented here within a biologically inspired neurosurgical system. read more
Lens Free Holographic Imaging for Urinary Tract Infection Screening

Lens Free Holographic Imaging for Urinary Tract Infection Screening

Lens Free Holographic Imaging for Urinary Tract Infection Screening 789 444 IEEE Transactions on Biomedical Engineering (TBME)
Holographic imaging can count red blood cells, white blood cells, crystals, casts, and bacteria suspended in urine. Particulate images can be reconstructed through the entire depth of a 2-mm channel. read more
Feature Identification Framework for Back Injury Risk in Repetitive Work with Application in Sheep Shearing

Feature Identification Framework for Back Injury Risk in Repetitive Work with Application in Sheep Shearing

Feature Identification Framework for Back Injury Risk in Repetitive Work with Application in Sheep Shearing 789 444 IEEE Transactions on Biomedical Engineering (TBME)
We developed an unsupervised feature selection framework for back injury risk using data collected from Australian sheep shearers. Our framework identifies features in line with literature and outperforms general methods. read more